Investigation of indoor daylight performance of the two-sided roof monitor system solution space
Investigation of indoor daylight performance of the two-sided roof monitor system solution space
Schmidlin, Flavio; Silva, Felipe Tavares da
Full Article:
The present study evaluated levels of zenith daylight and the incidence of solar radiation in an indoor environment with two-sided roof monitor system opening using a parametric geometric model, numerical simulations and machine learning techniques. It was used a climatic database from a locality with a hot and humid tropical climate, at low latitude in Brazil. The daylight performance was analyzed using the Useful Daylight Illuminances and the incident solar radiation with annual and daily maximum results. The study included analyzes with the zenith openings oriented to North-South and East-West, considering the photosensitive sensor meshes on the walls and floor. The results presented that the modeling process used can help the architectural design process in its dimension of natural illuminance and incidence of solar radiation in internal environments, showing optimized configurations for the room size and for the zenithal opening geometry.
The present study evaluated levels of zenith daylight and the incidence of solar radiation in an indoor environment with two-sided roof monitor system opening using a parametric geometric model, numerical simulations and machine learning techniques. It was used a climatic database from a locality with a hot and humid tropical climate, at low latitude in Brazil. The daylight performance was analyzed using the Useful Daylight Illuminances and the incident solar radiation with annual and daily maximum results. The study included analyzes with the zenith openings oriented to North-South and East-West, considering the photosensitive sensor meshes on the walls and floor. The results presented that the modeling process used can help the architectural design process in its dimension of natural illuminance and incidence of solar radiation in internal environments, showing optimized configurations for the room size and for the zenithal opening geometry.
Palavras-chave: - -
DOI: 10.5151/sigradi2022-sigradi2022_99
Referências bibliográficas
- [1]
Como citar:
Schmidlin, Flavio; Silva, Felipe Tavares da; "Investigation of indoor daylight performance of the two-sided roof monitor system solution space", p-237-248.
In: XXVI International Conference of the Iberoamerican Society of Digital Graphics.
São Paulo: Blucher,
2023.
ISSN 23186968,
DOI 10.5151/sigradi2022-sigradi2022_99
últimos 30 dias
104
downloads
124
visualizações
895
indexações
Sou autor desse trabalho
Você é citado neste trabalho?
Exportar citação - RefWork (RIS)
Copie a citação abaixo ou clique no botão Download para obter um arquivo com os dados
TY - CONF T1 - Investigation of indoor daylight performance of the two-sided roof monitor system solution space JO - Blucher Design Proceedings VL - 11 IS - 2 SP - 237 EP - 248 PY - 2023 T2 - XXVI International Conference of the Iberoamerican Society of Digital Graphics AU - , SN - 23186968 DO - http://dx.doi.org/10.5151/sigradi2022-sigradi2022_99 UR - www.proceedings.blucher.com.br/article-details/investigation-of-indoor-daylight-performance-of-the-two-sided-roof-monitor-system-solution-space-38494 KW - None ER -
Exportar citação - BibTeX(BIB)
Copie a citação abaixo ou clique no botão Download para obter um arquivo com os dados
@article{Schmidlin20144,
title="Investigation of indoor daylight performance of the two-sided roof monitor system solution space",
journal="Blucher Design Proceedings",
volume="11",
number="2",
pages="237 - 248",
year="2023",
note="",
issn="23186968",
doi="http://dx.doi.org/10.5151/sigradi2022-sigradi2022_99",
url="www.proceedings.blucher.com.br/article-details/investigation-of-indoor-daylight-performance-of-the-two-sided-roof-monitor-system-solution-space-38494",
author="Flavio Schmidlin", "Felipe Tavares da Silva",
keywords="None",
}
Exportar citação - Text(TXT)
Copie a citação abaixo ou clique no botão Download para obter um arquivo com os dados
Flavio Schmidlin, Felipe Tavares da Silva, Investigation of indoor daylight performance of the two-sided roof monitor system solution space, Blucher Design Proceedings, Volume 11, 2023, Pages 237-248, ISSN 23186968, http://dx.doi.org/10.5151/sigradi2022-sigradi2022_99 (www.proceedings.blucher.com.br/article-details/investigation-of-indoor-daylight-performance-of-the-two-sided-roof-monitor-system-solution-space-38494) Palavras-chave:: None;