Full Article - Open Access.

Idioma principal | Segundo idioma

Study of protective films for optical reflection systems with LEDs and photodiodes

Study of protective films for optical reflection systems with LEDs and photodiodes

Santos, Mariana Chagas Alcantara dos ; Ponte, Valmara Silveira ; Silva, Valéria Loureiro da ; Silva, Noemi Araújo Esquivelda ; Conceição, Wendy Barbosa ; Pepe, Iuri Muniz ; Mere, André Ali ; Buzzo, Everton ;

Full Article:

"Photoplethysmography devices use an optical system to extract informationfrom blood. The human body in direct contact with the system generates layers of oiland/or particles that significantly interfere with optical reading. To avoid this, it isnecessary to use a protective film and a cleaning method. The objective of this studyis to experimentally study the optical characteristics of six types of films made fromdifferent plastic materials that could be used as a protective film in a pulsephotoplethysmography system and, based on these results, define the material thatbest suits the system."

Full Article:

"Photoplethysmography devices use an optical system to extract informationfrom blood. The human body in direct contact with the system generates layers of oiland/or particles that significantly interfere with optical reading. To avoid this, it isnecessary to use a protective film and a cleaning method. The objective of this studyis to experimentally study the optical characteristics of six types of films made fromdifferent plastic materials that could be used as a protective film in a pulsephotoplethysmography system and, based on these results, define the material thatbest suits the system."

Palavras-chave: cleaning; protection; optics; photoplethysmography,

Palavras-chave: cleaning; protection; optics; photoplethysmography,

DOI: 10.5151/siintec2024-393156

Referências bibliográficas
  • [1] "1 Andriy Temko, Accurate Heart Rate Monitoring During Physical Exercises Using
  • [2] PPG, IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 64, NO. 9,
  • [3] SEPTEMBER 20172 ALIAN, A. Aymen; SHELLEY, Kirk H., Photoplethysmography, Best Practice &
  • [4] Research Clinical Anaesthesiology, Volume 28, Issue 4, 2014, Pages 395-406,
  • [5] ISSN 1521-6896, Available at: .
  • [6] 3 LEPPÄNNEN, Tino et. al. Pulse Oximetry: The Working Principle, Signal Formation
  • [7] and Applications. Advances in Experimental Medicine and Biology, vol 1384.
  • [8] Springer, Cham, 2022. Available at:
  • [9] Biodiesel: an overview. Journal of the Brazilian Chemical Society,
  • [10] 4TAMURA, Toshiyo et. al. Review Wearable Photoplethysmographic Sensors—Past
  • [11] and Present. Electronics, 2014, 3, 282-302; Available at:
  • [12]
  • [13] 5 Online Materials Information Resource - MatWeb. Available at:
  • [14] ."
Como citar:

Santos, Mariana Chagas Alcantara dos; Ponte, Valmara Silveira; Silva, Valéria Loureiro da; Silva, Noemi Araújo Esquivelda; Conceição, Wendy Barbosa; Pepe, Iuri Muniz; Mere, André Ali; Buzzo, Everton; "Study of protective films for optical reflection systems with LEDs and photodiodes", p. 82-89 . In: . São Paulo: Blucher, 2024.